AC-6b Capacitor Duty Contactor
Inrush Current Protection: Integrated resistors/Reactors limit switching surges.
Three Pt100 inputs for dry-type transformer windings, with fan control, alarm/trip signals and front-panel temperature settings.


Model: Panel-mounted type
Three Pt100 inputs for dry-type transformer windings, with fan control, alarm/trip signals and front-panel temperature settings.
| Temperature sensors | Three Pt100 platinum resistance sensors |
|---|---|
| Measuring range | -30 to 200 °C |
| Measuring accuracy | 0.5% FS ±1 digit |
| Resolution | 0.1 °C |
| Auxiliary power supply | 176–242 V AC; 50 Hz |
| Power consumption | 5 VA |
| Controller weight | <1 kg |
| Overall dimensions | 160 (W) × 80 (H) × 134 (D) mm |
| Panel cutout | 152 (W) × 76 (H) mm |
| Output arrangement | Confirm the fan-output arrangement and alarm/trip contact load ratings for the ordered configuration |
This panel-mounted controller monitors the three phase windings of an air-cooled dry-type transformer using Pt100 sensors. Switch between sequential phase temperatures and the highest winding temperature. The front panel provides temperature indication, status indicators and setting keys.
Use the technical specifications to check the auxiliary supply, temperature range and panel fit. Then specify the fan supply, number of fans and total rated current, together with the required alarm/trip circuit. Confirm the output arrangement, contact load ratings and final order code for the quoted unit.
Check the panel cutout and available installation depth before ordering. Request the confirmed terminal diagram and installation information for the selected controller, Pt100 sensor assembly and fan arrangement. Confirm which sensors, cables and mounting accessories are included in the quotation.
Send the transformer application, auxiliary supply, sensor requirements, fan voltage and total current, required alarm/trip settings, installation constraints, quantity and destination. Include any project-specific monitoring requirements for review.

Inrush Current Protection: Integrated resistors/Reactors limit switching surges.

APF Active power filter device integrates one or multiple active power filter modules, a control unit, circuit breakers, contactors, a cooling system, and other core components into a standard industrial enclosure, forming a complete, plug-and-play harmonic mitigation solution.

our Detuned Harmonic Filter Reactors are built using premium, low-loss silicon steel cores, high-grade winding insulation, and precision engineering techniques.