AC-6b Capacitor Duty Contactor
Inrush Current Protection: Integrated resistors/Reactors limit switching surges.
APF Active power filter device integrates one or multiple active power filter modules, a control unit, circuit breakers, contactors, a cooling system, and other core components into a standard industrial enclosure, forming a complete, plug-and-play harmonic mitigation solution.


Model: HY-APF-100/400-C
APF Active power filter device integrates one or multiple active power filter modules, a control unit, circuit breakers, contactors, a cooling system, and other core components into a standard industrial enclosure, forming a complete, plug-and-play harmonic mitigation solution.
| Compensating capacity | 50A/100A/150A/200A/300A(customizable)module,cabinet type free parallel expansion capacity |
|---|---|
| Connection mode | 3-phase 3-wire/3-phase 4-wire |
| Operating voltage | 380V(-40%~+20%) |
| 380V(-40%~+20%) | 50Hz(-10%~+10%) |
| System efficiency | >97% |
| Filtering capability | THDi(current distortion rate )<5% |
| Filter range | 2nd to 50th order |
| Response time | <300μS |
| Full response time | <10ms |
| Neutral filter capability | 3 times that of phase lines |
| IGBT frequency | 30kHz(equivalent frequency) |
| Self-diagnosis and protection functions | Yes |
| Communication interface | RS232 RS485 |
| Communication protocol | Modbus protocol |
| Installation method | Wall-mounted / Rack-mounted |
| Class of protection | IP30 |
| Lightning protection | 20kV |
| Number of Switching Operations | unlimited |
| CT transformer | 100/5~4000/5 |
| Ambient temperature | 0℃ to 40℃ |
| Storage temperature | -20℃~70℃ |
| Relative humidity | Max 95%,non-condensing |
| Altitude | ≤ 1500m; between 1500m and 4000m, power derated by 1% per 100m according to GB/T 3859.2 |
Its technical foundation is based on instantaneous reactive power theory and PWM (Pulse Width Modulation) technology.
1. Detection: External Current Transformers (CTs) continuously sample the load current signal in real-time.
2. Calculation: The built-in DSP (Digital Signal Processor) performs high-speed analysis on the sampled current, accurately calculating the harmonic, reactive, or negative-sequence current components that need to be compensated.
3. Generation and Injection: The controller drives the IGBT (Insulated-Gate Bipolar Transistor) power converter to generate a compensation current that is equal in magnitude and opposite in direction to the detected harmful current.
4. Cancellation: This compensation current is injected into the grid through a reactor, where it cancels out the harmonic currents generated by the load at the grid side. Ultimately, the current drawn from the grid becomes a clean sine wave.


Inrush Current Protection: Integrated resistors/Reactors limit switching surges.

our Detuned Harmonic Filter Reactors are built using premium, low-loss silicon steel cores, high-grade winding insulation, and precision engineering techniques.

Dry-type iron-core reactors are critical electrical equipment in power systems, used for compensating capacitive reactive power, suppressing harmonic currents, and limiting short-circuit currents.