AC-6b Capacitor Duty Contactor
Inrush Current Protection: Integrated resistors/Reactors limit switching surges.
Thermoelectric dehumidifier for electrical cabinets and switchgear, with adjustable humidity control, condensate drainage, defrosting and RS485 communication.


Model: Intelligent Cabinet Dehumidifier
Thermoelectric dehumidifier for electrical cabinets and switchgear, with adjustable humidity control, condensate drainage, defrosting and RS485 communication.
| Product type | Intelligent thermoelectric cabinet dehumidifier / anti-condensation device |
|---|---|
| Power supply | AC/DC 220 V |
| Dehumidification power options | 30 W, 45 W or 60 W |
| Dehumidification rate | 450 mL/day for the 60 W version at 35 °C and 80% RH |
| Humidity measurement range | 5–95% RH; accuracy ±5% RH |
| Temperature measurement range | −20 to 60 °C; accuracy ±1 °C |
| External heating power range | 50–500 W; heating output or alarm output must be selected |
| Communication interface | RS485; confirm the communication protocol for the selected version |
| Control output | Dry contact, configured for external heating or alarm |
| Drain tube | Silicone, diameter 8 mm, length 1 m |
| Mounting | 35 mm rail mounting; confirm the outline and mounting arrangement for the selected version |
This smart anti-condensation device uses semiconductor thermoelectric cooling to remove moisture from the air inside enclosed electrical cabinets. A fan draws humid air across the cooling element, water vapour condenses, and the collected water drains outside the cabinet through a tube. It is intended for managing moisture and condensation inside switchgear and similar electrical enclosures.
The humidity load starts when humidity rises above Ho1 and stops when it falls below Ho2, with Ho1 set higher than Ho2. For external-heater control, heating starts below Co1 and stops above Co2, with Co1 set lower than Co2. The heating function controls an external heater.
If humidity has not fallen to the configured operating threshold after 10 hours, the fault indicator flashes. Review the moisture load and dehumidification capacity for the installation. Fault codes and a fault indicator help identify power, fan or dehumidification-system faults.
| Parameter | Specification |
|---|---|
| Product type | Intelligent thermoelectric cabinet dehumidifier / anti-condensation device |
| Power supply | AC/DC 220 V |
| Dehumidification power options | 30 W, 45 W or 60 W |
| Dehumidification rate | 450 mL/day for the 60 W version at 35 °C and 80% RH |
| Humidity measurement range | 5–95% RH; accuracy ±5% RH |
| Temperature measurement range | −20 to 60 °C; accuracy ±1 °C |
| External heating power range | 50–500 W; heating output or alarm output must be selected |
| Communication interface | RS485; confirm the communication protocol for the selected version |
| Control output | Dry contact, configured for external heating or alarm |
| Drain tube | Silicone, diameter 8 mm, length 1 m |
| Mounting | 35 mm rail mounting; confirm the outline and mounting arrangement for the selected version |
The 450 mL/day figure applies to the stated 60 W test condition. Actual water removal depends on cabinet temperature, humidity and moisture ingress; it is not a capacity claim for every environment or power option.
| Code | Function | Factory setting |
|---|---|---|
| Ho1 | Humidity ON | 85% RH |
| Ho2 | Humidity OFF | 75% RH |
| Co1 | Temperature ON | 5 °C |
| Co2 | Temperature OFF | 15 °C |
| dH | Humidity offset | 0 |
| Add | Device address | 01 |
The factory mode combines dehumidification with heating control. Select either the external-heating output or the alarm output; these are alternative uses of the output. Set the humidity and temperature thresholds to suit the cabinet and connected equipment.
The rail-mounted arrangement uses a standard 35 mm rail fixed to the panel. Keep the air outlet clear and route the condensate drain outside the cabinet. Obtain the outline drawing and terminal diagram for the selected version before cabinet design or wiring.
The RS485 interface supports transmission of temperature, humidity, settings and fault information. Confirm the communication protocol and terminal arrangement for the ordered version before integration.
Please specify the required product configuration when requesting a quotation:

Inrush Current Protection: Integrated resistors/Reactors limit switching surges.

APF Active power filter device integrates one or multiple active power filter modules, a control unit, circuit breakers, contactors, a cooling system, and other core components into a standard industrial enclosure, forming a complete, plug-and-play harmonic mitigation solution.

our Detuned Harmonic Filter Reactors are built using premium, low-loss silicon steel cores, high-grade winding insulation, and precision engineering techniques.