AC-6b Capacitor Duty Contactor
Inrush Current Protection: Integrated resistors/Reactors limit switching surges.
Single-phase active-energy metering with a 7-digit LCD, RS485 Modbus-RTU communication and DIN-rail installation. Check the selected voltage, current rating and accuracy class before ordering.


Model: DDS/D/C
Single-phase active-energy metering with a 7-digit LCD, RS485 Modbus-RTU communication and DIN-rail installation. Check the selected voltage, current rating and accuracy class before ordering.
| Series marking on pictured unit | DDS/D/C |
|---|---|
| Measured energy | Single-phase active energy |
| Rated voltage options (manual) | 220 V / 230 V |
| Current ratings, Ib (Imax) (manual) | 5(20) A; 10(40) A; 15(60) A; 20(80) A |
| Rated frequency (manual) | 50 / 60 Hz |
| Accuracy class options (manual) | Class 1.0 or Class 2.0 |
| Operating supply voltage | 0.7 Un to 1.2 Un; Un = nominal voltage |
| Display | 7-digit LCD; configurable as 6 integer digits and 1 decimal digit |
| Communication interface / protocol | RS485 / Modbus-RTU |
| Factory-default baud rate | 9600 bit/s |
| Serial format | 8 data bits, no parity, 1 stop bit (8N1) |
| Pulse output | Optically isolated passive output |
| Reverse-energy treatment | Reverse energy is accumulated as forward energy |
| Mounting | DIN rail |
| Dimensions (H x W x D) | 104 x 36 x 68 mm |
| Ambient temperature | -25°C to +55°C |
| Relative humidity | 25% to 95% |
| Pictured configuration | 220 V; 10(40) A; 50 Hz |
| Pulse constant on pictured nameplate | 1600 imp/kWh; check the nameplate of the supplied configuration |
This HUAYI DIN-rail meter measures single-phase active energy and provides local LCD readings, RS485 Modbus-RTU communication and an optically isolated passive pulse output.
The photograph shows a unit marked DDS/D/C, 220 V, 10(40) A, 50 Hz and 1600 imp/kWh. The English manual lists additional voltage, current and accuracy options. Confirm your required configuration when requesting a quotation.
Overall dimensions: 104 × 36 × 68 mm (height × width × depth). Open the technical drawing below to inspect the dimensions and terminal diagram.
Read the supplied English manual as individual page images. Each link opens a full-size image.
Which communication protocol does it use?
RS485 with Modbus-RTU. The manual gives a factory-default baud rate of 9600 and an 8N1 serial format.
Does it keep separate import and export energy totals?
The manual states that reverse energy is accumulated as forward energy. If separate import/export registers are required, ask us to confirm a suitable configuration before ordering.
What information should I include in an inquiry?
Provide the required voltage, current rating Ib (Imax), frequency, accuracy class, quantity and communication requirements. Include your panel arrangement or installation requirements if relevant.

Inrush Current Protection: Integrated resistors/Reactors limit switching surges.

APF Active power filter device integrates one or multiple active power filter modules, a control unit, circuit breakers, contactors, a cooling system, and other core components into a standard industrial enclosure, forming a complete, plug-and-play harmonic mitigation solution.

our Detuned Harmonic Filter Reactors are built using premium, low-loss silicon steel cores, high-grade winding insulation, and precision engineering techniques.