Low Voltage Power Factor Correction & Power Quality Solutions
Iron Casing Electrical Capacitor

Model: BSMJ-460-10-3-all

Genuine power Explosion-proof Iron Casing Electrical Capacitor is assembled into an integrated unit and encapsulated in an explosion-proof square metal housing, it has large heat dissipation area and excellent heat dissipation performance. Each capacitor cell is wound using high-quality thickened metallized film, and features a unique built-in fuse protection structure. The components are encapsulated in thermosetting resin material, providing excellent sealing, resistance to aging, flame retardancy, and environment- friendly.

Technical Specifications

Altitude:≤2000m
Rated capacity:5~ 50kVar
Ambient temperature:-25°C /55°C
Rated frequency:50Hz
Humidity:35°C ≤90%
Capacitance deviation:-3~+ 5%
Rated voltage:230V~690V
Allowable overcurrent:1.3ln
Standard:EN60831-1&2, IEC60831-1&2
Maximum allowable overvoltage:1.1Un
Tangent value of loss angle:<0.0012

Key Features

Applications

1. Industrial Manufacturing Plants Motors, transformers, welding machines, injection-moulding and press lines all draw reactive power that lowers the plant power factor. Capacitor banks restore the power factor close to unity, release transformer capacity and eliminate utility low-PF penalties.2. Commercial Buildings & HVAC Systems Chillers, air-handling units, elevators and lighting loads in offices, malls and supermarkets cause reactive demand that inflates the electricity bill. Automatic capacitor banks reduce kVA demand, cut line losses and stabilise voltage on long internal feeders.3. Data Centres & Telecom Facilities UPS systems, CRAC units and switched-mode server power supplies generate both reactive power and harmonics. Detuned capacitor banks (capacitors with 7% series reactors) provide safe compensation in these harmonic-rich networks and free up generator and UPS capacity.4. Water Supply & Wastewater Treatment Plants Large pumps and blowers frequently run at partial load with a poor power factor. Capacitor banks improve the power factor, reduce current in long cable runs and lower energy losses across the plant distribution network.5. Hotels, Hospitals & Public Infrastructure HVAC, kitchens, laundry equipment and medical imaging systems operate simultaneously and push the power factor down. Automatic compensation keeps it above 0.95, avoids utility penalties and protects sensitive equipment from voltage fluctuation.6. Solar PV & Renewable Energy Plants Grid codes require a defined power factor at the point of connection, but inverters cannot supply reactive power when they are offline at night. Capacitor banks provide steady reactive support and help the plant stay compliant with utility requirements.7. Metal Processing, Welding & Induction Heating Arc furnaces, induction heaters and welding transformers have very low power factors and high harmonic content. Detuned capacitor banks with series reactors deliver reactive power safely, reducing flicker, demand charges and cable heating.8. Mining, Cement & Heavy Industry Crushers, mills, conveyors and hoists on remote or weak grids draw heavy reactive current. Capacitor banks improve voltage regulation at the end of long feeders, cut cable losses and reduce fuel consumption on captive diesel or gas generation.9. Ports, Airports & Rail Systems Ship-to-shore cranes, RTG cranes, terminal conveyors, shore power and station HVAC create fast-fluctuating reactive demand. Thyristor-switched capacitor steps respond within milliseconds and hold the power factor stable under rapid load changes.10. Agriculture, Irrigation & Cold Storage Irrigation pump sets and refrigeration compressors on long rural feeders often suffer from low voltage and high line current. Capacitor banks raise voltage at the pump terminals, reduce line losses and improve starting reliability.

Product Description

Installation Size:
3-4.png
Note: The parameters are typical values for reference, can be customized according to customer's requirements, we reserve the right to change the data.